Return-Path: <email_C908876B-F91E-4785-A37A-8080905CA754O@bidmail.com>
Delivered-To: info@sterlingcal.com
Received: from reseller401.webserversystems.com
	by reseller401.webserversystems.com with LMTP
	id QFKIHMLo+mKpNQIAchKAPA
	(envelope-from <email_C908876B-F91E-4785-A37A-8080905CA754O@bidmail.com>)
	for <info@sterlingcal.com>; Mon, 15 Aug 2022 19:45:54 -0500
Return-path: <email_C908876B-F91E-4785-A37A-8080905CA754O@bidmail.com>
Envelope-to: info@sterlingcal.com
Delivery-date: Mon, 15 Aug 2022 19:45:54 -0500
Received: from mail.bidmail.com ([208.97.57.222]:64379)
	by reseller401.webserversystems.com with esmtps  (TLS1.2) tls TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384
	(Exim 4.94.2)
	(envelope-from <email_C908876B-F91E-4785-A37A-8080905CA754O@bidmail.com>)
	id 1oNkiQ-000bpH-0h
	for info@sterlingcal.com; Mon, 15 Aug 2022 19:45:54 -0500
DKIM-Signature: a=rsa-sha256; t=1660610740; x=1661215540; s=m1024; d=bidmail.com; c=relaxed/relaxed; v=1; bh=nColIrKsguS9xqbEHGb0seDxUB7WCvOvSGbuKW+WxYw=; h=From:Subject:Date:Message-ID:To:MIME-Version:Content-Type;
   b=GLExUUtDkK/TiPm2mEOP/5beD/pzzxZIUyhwmBX2ti/ueVYiwl4YJcj8O1FC1RNv6fVjyw0BT/e9+xEk569HDYONmZXL2VnkAobUbCoYdV0/Dy7lsZzox+Kymqi0iXfFbuL65BIHEJl19/kaAZT2kb2/eupSJTWTX0jqjziX/Ak=
Received: from mail.corp.bidmail.com ([208.97.57.222])
        by mail.bidmail.com (12.2.0 build 2 x64) with ASMTP id 202208151845404379
        for <info@sterlingcal.com>; Mon, 15 Aug 2022 18:45:40 -0600
Subject: Silverstrand Construction: Construct C-130J Flight Simulator Facility - Amendment #2
List-Unsubscribe: <mailto: unsubscribe@bidmail.com?subject=unsubscribe%20C908876B-F91E-4785-A37A-8080905CA754>
From: Silverstrand Construction <email_C908876B-F91E-4785-A37A-8080905CA754O@bidmail.com>
To: info@sterlingcal.com
Content-Type: multipart/mixed; boundary="----=_NextPart_000386eb02078707e6"
MIME-Version: 1.0
Date: Mon, 15 Aug 2022 18:45:40 -0600
Message-ID: <57c7e6e4e42e43c554b4f94a9d66e063@bidmail.com>
X-Spam-Status: No, score=-0.4
X-Spam-Score: -3
X-Spam-Bar: /
X-Spam-Flag: NO


------=_NextPart_000386eb02078707e6
Content-Type: multipart/related; boundary="----=_NextPart_000386ec02078807e6"


------=_NextPart_000386ec02078807e6
Content-Type: multipart/alternative; boundary="----=_NextPart_000386ed02078907e6"


------=_NextPart_000386ed02078907e6
Content-Type: text/plain





Addenda



	
	
		
			
			&nbsp;
			
				
					
					
					
						
							
							
								
									Addenda
									Construct C-130J Flight Simulator Facility
								
							
							
						
						
							
							&nbsp;
							
						
						
							
							
								
									
										
											To
											Sterling Construction Co. 
											Andrew Sterling (info@sterlingcal.com)
											
											9025 Wilshire Blvd Suite 301
											Beverly Hills CA 90211 
										
									
									
										
											From
											Silverstrand Construction
											Bill Bloom (bill@sscbuild.com)
											10065 Old Grove Road, STE 200
											San Diego CA 92131
											P: (858) 220-9912 F: (858) 689-2334
											
										
									
								
							
							
						
						
							
							
								
								Message 
								
									
										
										
											Team -&nbsp;

Please see issued amendment&nbsp;#2 for use.

&nbsp;

Respectfully,

Bill Bloom

Senior Estimator



10065 Old Grove Road, Ste. 200
San Diego, CA. 92131
Cell:&nbsp;858-649-3152

silverstrandconstruction.com

8(a) &bull;&nbsp; HUBZone &bull;&nbsp; MBE &bull;&nbsp; LEED
CA Lic NO. 927409
											
											
											
										
									
								
								
							
						
						






Documents





Project Files











						
							
							
								
								
								Project
								Construct C-130J Flight Simulator Facility
								Bid Date/Time
								August 16, 2022 
								06:00 pm
								Location
								113 Mulcahey Drive 
								Port Hueneme CA 93041
								Trade(s)
								030000 - Concrete
								Estimator
								Bill Bloom
								Scope/Comments
								Provide all plant, labor, new and current material, transportation, tools, equipment, appliances, supplies, services, permits, insurance, and supervision necessary to construct a new 11,225 SF facility for a C-130J flight simulator, at Channel Islands Air National Guard Station (ANGS), CA.

This project has Additive Bid Items (ABI) and, the Government will determine apparent low bidder in accordance&nbsp;with the procedure described in DFARS Provision 252.236-7007, Additive or Deductive Items. The following ABIs are included with the following order of priority:

1. Provide back-up chiller (CH-2) with protective bollards.
2. Provide bridge crane (machine &amp; rails only) with smaller-sized overhead coiling exterior door (in lieu of no
crane with larger sized overhead coiling exterior door).
3. Provide breathing air compressor in simulator motion bay.
4. Provide 2&quot; clad (to match building xxterior) 8&quot; CMU wall (2 segments) at mechanical equipment yard (in lieu&nbsp;of chain-link fencing (2 Segments) with visual slats.
5. Provide epoxy paint flooring in mechanical, electrical, and communications rooms, and simulator motion
bay (in lieu of coated concrete).
6. Provide scheduled interior floor finishes (in lieu of coated concrete; not including epoxy or anti-static flooring&nbsp;in communication room, or porcelain tile in restrooms and janitor closet).
7. Provide illuminated unit insignia sign (with controls) on building exterior.
8. Provide 2&quot; fabricated wall panels on building exterior (in lieu of 2&quot; EIFS).
9. Provide translucent fiberglass wall panels (horizontal clarestory installation) (in lieu of scheduled
materials/wall system).
10. Provide translucent fiberglass wall panels (vertical, 2 stripe installation) (in lieu of scheduled materials/wall&nbsp;system).
11. Proved 2&quot; clad (to match building exterior) 8&quot; CMU wall (3 segments) trash dumpster enclosure with&nbsp;ornamental gate.
12. Provide additional concrete sidewalk pavements as indicated on drawings.
13. Provide landscaping around building (in lieu of specified native grass).

&nbsp;

Project&nbsp;Solicitation Link:

https://sam.gov/opp/ef24889d3718436faa25b06f8fdc0b27/view#attachments-links
							
							
						
					
					
				
			
			
		
	
	
	




------=_NextPart_000386ed02078907e6
Content-Type: text/html

<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta content="text/html; charset=utf-8" http-equiv="Content-Type" />
<title>Addenda</title>
</head>
<body>
<div marginheight="0" marginwidth="0" style="margin: 0; padding: 0; background-color: #ededed; width: 100%!important; line-height: 100%!important; font-family: Arial;">
	<center>
	<table border="0" cellpadding="0" cellspacing="10" height="100%" style="margin: 0; padding: 0; background-color: #ededed; width: 100%!important; line-height: 100%!important; height: 100%!important" width="100%">
		<tr>
			<td align="middle" style="border-collapse: collapse; padding-top: 5px; padding-bottom: 5px;" valign="top">
			<p style="margin-bottom: 0; margin: 0;">&nbsp;</p>
			<table border="0" cellpadding="0" cellspacing="0" style="border-top: 0px solid transparent; border-radius: 7px; background-color: #ffffff; min-width: 370px;">
				<tr>
					<td align="center" style="border-collapse: collapse" valign="top">
					
					<table border="0" cellpadding="0" cellspacing="0" style="margin-left: 10px; margin-right: 10px;">
						<tr>
							<td style="border-collapse: collapse; background-color: #ffffff" valign="top">
							<div style="color: #505050; font-family: Arial; text-align: left; max-width: 640px !important;">
								<div style="width: 100%; background-color: #ffffff; padding-top: 5px; padding-bottom: 5px; margin-top: 10px;"><div align="center"><img src="https://www.bidmail.com/kbimages/3688349/logo.png" alt="Silverstrand Construction"/>
									<h1 style="text-align: center">Addenda</h1>
									<h2 style="text-align: center; line-height: 164%;">Construct C-130J Flight Simulator Facility</h2>
								</div>
							</div>
							</td>
						</tr>
						<tr>
							<td style="background-color: #ffffff" >
							&nbsp;
							</td>
						</tr>
						<tr>
							<td style="border-collapse: collapse; background-color: #ffffff" valign="top">
							<div style="color: #505050; font-family: Arial; text-align: left; max-width: 640px !important;">
								<div style="margin-top: 10px; margin-bottom: 10px; width=100% ;">
									<table align="left" cellpadding="0" cellspacing="0" class="msoFix" style="padding-bottom: 10px" width="310">
										<tr>
											<td style="color: #505050; font-family: Arial; text-align: left;" ><strong>To</strong><br />
											Sterling Construction Co. <br />
											Andrew Sterling (info@sterlingcal.com)
											<br />
											9025 Wilshire Blvd Suite 301<br />
											Beverly Hills CA 90211 </td>
										</tr>
									</table>
									<table align="left" cellpadding="0" cellspacing="0" class="msoFix" style="padding-bottom: 10px" width="310">
										<tr>
											<td style="color: #505050; font-family: Arial; text-align: left;" ><strong>From</strong><br />
											Silverstrand Construction<br />
											Bill Bloom (bill@sscbuild.com)<br />
											10065 Old Grove Road, STE 200<br />
											San Diego CA 92131<br />
											P: (858) 220-9912 F: (858) 689-2334
											</td>
										</tr>
									</table>
								</div>
							</div>
							</td>
						</tr>
						<tr>
							<td style="border-collapse: collapse; background-color: #ffffff" valign="top">
							<div style="color: #505050; font-family: Arial; text-align: left; max-width: 640px !important;">
								<hr style="color: #e6e8e6; background-color: #e6e8e6; min-height: 1px; border: 0; margin-top: 5px; margin-bottom: 10px;" />
								<strong>Message</strong> <!--[if (gte mso 9)|(IE)]>
								<table>
									<tr>
										<td width="600"><![endif]-->
										<div style="max-width: 600px;">
											<p>Team -&nbsp;</p>

<p>Please see issued amendment&nbsp;#2 for use.</p>

<p>&nbsp;</p>

<p>Respectfully,</p>

<p>Bill Bloom</p>

<p>Senior Estimator</p>

<p><img src="https://ci5.googleusercontent.com/proxy/TtzjWl7T4ob40wgTwjERP_U74CyH8y0Q_WLwcBtoJ2EIxDRyhiaBNr_JFszCuZz2bD9Z_r_2peARZOVJ73fqH6TKBE_1RH4ehzayzNKBa7yI_zDu1niLpbE4C3eifRKhv4W-d2ZSJfpQ-iNY2ByvvF31G4fAuaQkXmQE1CZVuB-oKxJSGyjR7SoL8d0YWHPKpvHWotaw6QHgL-XrOsofPA=s0-d-e1-ft#https://docs.google.com/uc?export=download&amp;id=17cYHkiWluG_Lh9s-XL4eHmMk8_R8vE1E&amp;revid=0B3Tuv0Blf1JIaGdDeDk0bFNiNVNVcXlUQXA1Q0VvRFlaeS9rPQ" style="height:54px; width:200px" /></p>

<p>10065 Old Grove Road, Ste. 200<br />
San Diego, CA. 92131<br />
Cell:&nbsp;858-649-3152</p>

<p><a href="http://silverstrandconstruction.com/" target="_blank">silverstrandconstruction.com</a></p>

<p>8(a) &bull;&nbsp; HUBZone &bull;&nbsp; MBE &bull;&nbsp; LEED<br />
CA Lic NO. 927409</p>
											<div>
											</div>
											<!--[if mso]></div>
										</td>
									</tr>
								</table>
								<![endif]--></div>
							</td>
						</tr>
						<tr>
<td style="border-collapse: collapse; background-color: #ffffff;" valign="top">
<div style="color: #505050; font-family: Arial; text-align: left; max-width: 640px !important;"><hr style="color: #e6e8e6; background-color: #e6e8e6; min-height: 1px; border: 0; margin-top: 5px; margin-bottom: 10px;" />
<div style="position: relative; padding: 0px; padding-bottom: 10px;">
<table align="left" cellpadding="0" cellspacing="0" class="msoFix" style="padding-bottom: 10px; width: 310px;">
<tbody>
<tr>
<td style="color: #505050; font-family: Arial; text-align: left;"><strong>Documents</strong></td>
<td style="color: #505050; font-family: Arial; text-align: left;"></td>
<td style="color: #505050; font-family: Arial; text-align: left;">
<table cellpadding="0" cellspacing="0" style="width: 150px;">
<tbody>
<tr>
<td><a href="http://share.bidmail.com/files-inter.aspx?cmd=C908876B-F91E-4785-A37A-8080905CA754" style="font-size: 16px; font-family: Helvetica, Arial, sans-serif; color: #ffffff; text-decoration: none; border-radius: 3px; -webkit-border-radius: 3px; -moz-border-radius: 3px; background-color: #0033ff; border-top: 7px solid #0033ff; border-bottom: 7px solid #0033ff; border-right: 18px solid #0033ff; border-left: 18px solid #0033ff; display: inline-block;"><strong>Project Files</strong></a></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
</div>
</div>
</td>
</tr>
						<tr>
							<td style="border-collapse: collapse; background-color: #ffffff" valign="top">
							<div style="color: #505050; font-family: Arial; text-align: left; max-width: 640px !important;">
								<hr style="color: #e6e8e6; background-color: #e6e8e6; min-height: 1px; border: 0; margin-top: 5px; margin-bottom: 10px;" />
								<br />
								<strong>Project</strong>
								<p style="margin: 1em 0; margin-bottom: 16px">Construct C-130J Flight Simulator Facility</p>
								<strong>Bid Date/Time</strong>
								<p style="margin: 1em 0; margin-bottom: 16px">August 16, 2022 
								06:00 pm</p>
								<strong>Location</strong>
								<p style="margin: 1em 0; margin-bottom: 16px">113 Mulcahey Drive 
								Port Hueneme CA 93041</p>
								<strong>Trade(s)</strong>
								<p style="margin: 1em 0; margin-bottom: 16px">030000 - Concrete</p>
								<strong>Estimator</strong>
								<p style="margin: 1em 0; margin-bottom: 16px">Bill Bloom</p>
								<strong>Scope/Comments</strong>
								<p style="margin: 1em 0; margin-bottom: 16px"><p>Provide all plant, labor, new and current material, transportation, tools, equipment, appliances, supplies, services, permits, insurance, and supervision necessary to construct a new 11,225 SF facility for a C-130J flight simulator, at Channel Islands Air National Guard Station (ANGS), CA.</p>

<p>This project has Additive Bid Items (ABI) and, the Government will determine apparent low bidder in accordance&nbsp;with the procedure described in DFARS Provision 252.236-7007, Additive or Deductive Items. The following ABIs are included with the following order of priority:</p>

<p>1. Provide back-up chiller (CH-2) with protective bollards.<br />
2. Provide bridge crane (machine &amp; rails only) with smaller-sized overhead coiling exterior door (in lieu of no<br />
crane with larger sized overhead coiling exterior door).<br />
3. Provide breathing air compressor in simulator motion bay.<br />
4. Provide 2&quot; clad (to match building xxterior) 8&quot; CMU wall (2 segments) at mechanical equipment yard (in lieu&nbsp;of chain-link fencing (2 Segments) with visual slats.<br />
5. Provide epoxy paint flooring in mechanical, electrical, and communications rooms, and simulator motion<br />
bay (in lieu of coated concrete).<br />
6. Provide scheduled interior floor finishes (in lieu of coated concrete; not including epoxy or anti-static flooring&nbsp;in communication room, or porcelain tile in restrooms and janitor closet).<br />
7. Provide illuminated unit insignia sign (with controls) on building exterior.<br />
8. Provide 2&quot; fabricated wall panels on building exterior (in lieu of 2&quot; EIFS).<br />
9. Provide translucent fiberglass wall panels (horizontal clarestory installation) (in lieu of scheduled<br />
materials/wall system).<br />
10. Provide translucent fiberglass wall panels (vertical, 2 stripe installation) (in lieu of scheduled materials/wall&nbsp;system).<br />
11. Proved 2&quot; clad (to match building exterior) 8&quot; CMU wall (3 segments) trash dumpster enclosure with&nbsp;ornamental gate.<br />
12. Provide additional concrete sidewalk pavements as indicated on drawings.<br />
13. Provide landscaping around building (in lieu of specified native grass).</p>

<p>&nbsp;</p>

<p><strong>Project&nbsp;Solicitation Link:</strong></p>

<p><strong>https://sam.gov/opp/ef24889d3718436faa25b06f8fdc0b27/view#attachments-links</strong></p></p>
							</div>
							</td>
						</tr>
					</table>
					</td>
				</tr>
			</table>
			</td>
		</tr>
	</table>
	<br />
	</center></div>
<br />
</body>
</html>

------=_NextPart_000386ed02078907e6--

------=_NextPart_000386ec02078807e6--

------=_NextPart_000386eb02078707e6--
